Biolox Delta Ceramic Femoral Head 36mm Plus 0 Neck Lenght

Pdf Fracture Of A Biolox Delta Ceramic Femoral Head A Case Report And Update Of The Literature

Pdf Fracture Of A Biolox Delta Ceramic Femoral Head A Case Report And Update Of The Literature

Https Fda Report Pma P150030 15 P150030d Pdf

Https Fda Report Pma P150030 15 P150030d Pdf

Home

Home

Https Www Smith Nephew Com Global Assets Pdf Products Surgical Echelon Primary St 03019 Pdf

Https Www Smith Nephew Com Global Assets Pdf Products Surgical Echelon Primary St 03019 Pdf

Http Synthes Vo Llnwd Net O16 Llnwmb8 Us 20mobile Synthes 20north 20america Product 20support 20materials Catalogs Approved Component Guide 0612 91 511r3 Pdf

Http Synthes Vo Llnwd Net O16 Llnwmb8 Us 20mobile Synthes 20north 20america Product 20support 20materials Catalogs Approved Component Guide 0612 91 511r3 Pdf

Http Www Smith Nephew Com Global Surgicaltechniques Recon Ep Fit Plus 01465 Pdf

Http Www Smith Nephew Com Global Surgicaltechniques Recon Ep Fit Plus 01465 Pdf

Http Www Smith Nephew Com Global Surgicaltechniques Recon Ep Fit Plus 01465 Pdf

Most of the biolox forte head fractures were related to a design problem of the 28 mm short neck ceramic head.

Biolox delta ceramic femoral head 36mm plus 0 neck lenght. This issue means patients who have received a hip replacement using these biolox forte 36 mm alumina ceramic heads may be at increased risk of requiring revision surgery due to dislocation or. Please confirm that you are a member of this professional group. Two complaints reported that the biolox delta ts ceramic femoral articul eze12 14 36mm 12 head product code 1365 36 740 did not fit like the trial. The titanium adapters have an internal 12 14 taper that mates with the femoral stem while the option heads have a taper designed to mate with the adapters.

Biolox delta is the only ceramic with 15 years of successful clinical experience and with more than 8 million sold components. The loosening refers to tissue tension and not the taper connection between the femoral head and stem. Biolox delta ceramic. The option is comprised of two components.

Biolox delta ceramic heads sizes and specs. The study device consisted of a biolox delta ceramic head pink. The biolox delta option ceramic head features a titanium neck sleeve designed to allow surgeons to utilize a ceramic head in either primary or. 28 32 36 and 40 mm head diameters are available.

Ceramic femoral head 36 mm slt taper long neck part number 26000012 these products had been manufactured to this specification for more than 15 years. Low wear with multiple liner options. You are about to access the professional information area of the biolox website which is solely for medical and pharmaceutical professionals. The definite hip construct felt loose.

650 1057 biolox delta option head 36mm 650 1058 biolox delta option head 40mm 650 1157 delta ceramic femoral head ø28 3mm t1 650 1158 delta ceramic femoral head ø28 0mm t1 650 1159 delta ceramic femoral head ø28 3mm t1 650 1160 delta ceramic femoral head ø32 6mm t1 650 1161 delta ceramic femoral head ø32 3mm t1. The biolox delta component is a traditional one piece ceramic head indicated for primary hip arthroplasty only. He had a 28 mm 3 mm neck femoral head and was revised to a polyethylene liner with a standard neck 32 mm cobalt chrome head. P biomet offers both the biolox delta and the biolox delta option ceramic femoral heads.

Size mm offset mm 28 3 50. The distance between the bore corner and the outer surface is thin in the 28 mm short neck ceramic head which might lead to a brittle fracture.

Https Jri Ltd Com Wp Content Uploads 2017 08 Furlong Optec V8 030817 Singles Pdf

Https Jri Ltd Com Wp Content Uploads 2017 08 Furlong Optec V8 030817 Singles Pdf

Pdf Mid Term Results Of The Biolox Delta Ceramic On Ceramic Total Hip Arthroplasty

Pdf Mid Term Results Of The Biolox Delta Ceramic On Ceramic Total Hip Arthroplasty

Https Www Smith Nephew Com Global Assets Pdf Products Surgical Echelon Revision St 02194 Pdf

Https Www Smith Nephew Com Global Assets Pdf Products Surgical Echelon Revision St 02194 Pdf

Http Www Pachp Com Wp Content Uploads 2015 07 Metafix Surgical Technique Pdf

Http Www Pachp Com Wp Content Uploads 2015 07 Metafix Surgical Technique Pdf

Pdf Alternative Bearing Surfaces Alumina Ceramic Bearings For Total Hip Arthroplasty

Pdf Alternative Bearing Surfaces Alumina Ceramic Bearings For Total Hip Arthroplasty

Https Www Smith Nephew Com Documents Nl Bicon Surgicaltechnique Pdf

Https Www Smith Nephew Com Documents Nl Bicon Surgicaltechnique Pdf

Https Www Arthroplastytoday Org Article S2352 3441 20 30011 X Pdf

Https Www Arthroplastytoday Org Article S2352 3441 20 30011 X Pdf

Https Www Smith Nephew Com Documents Italy Ibooks Adr R3 20design 20rationale 20intl 20 71381345 Reva 1012 Pdf

Https Www Smith Nephew Com Documents Italy Ibooks Adr R3 20design 20rationale 20intl 20 71381345 Reva 1012 Pdf

Https Jri Ltd Com Wp Content Uploads 2017 08 6721 20yr Warranty Brochure Tc Pr Pdf

Https Jri Ltd Com Wp Content Uploads 2017 08 6721 20yr Warranty Brochure Tc Pr Pdf

Rejuvenate Total Hip System Surgical Protocol Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility Pdf Free Download

Rejuvenate Total Hip System Surgical Protocol Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility Pdf Free Download

Https Www Smith Nephew Com Global Surgicaltechniques Recon 71380839 20reflection 20interfit 20st Pdf

Https Www Smith Nephew Com Global Surgicaltechniques Recon 71380839 20reflection 20interfit 20st Pdf

Http Www Bizwan Com Mydoc Stryker Hip 015 20exeter 20v40 20femoral 20stem 20using 20modular 20broach 20surgical 20technique 20for 20us Pdf

Http Www Bizwan Com Mydoc Stryker Hip 015 20exeter 20v40 20femoral 20stem 20using 20modular 20broach 20surgical 20technique 20for 20us Pdf

Revision Surgery For Failed Hip Resurfacing Sciencedirect

Revision Surgery For Failed Hip Resurfacing Sciencedirect

Link Hip Prostheses

Link Hip Prostheses

Source : pinterest.com